loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

PVC Laboratory High Speed Mixer for PVC Powder Formulation

Availability:
Quantity:

Product Description

Product Overview

PVC formulation development requires careful preparation of resin and various additives before extrusion or further processing.

Depending on the final product and processing requirements, a PVC dry blend may contain PVC resin, stabilizers, lubricants, pigments, fillers and processing aids. These ingredients need to be mixed according to a defined formulation before the material is evaluated in downstream production.

The Chenxing SHR-10A 10L PVC Laboratory High Speed Mixer is designed for small-batch PVC powder mixing and formulation development.

With a 10L total vessel capacity and approximately 7L effective working volume, the SHR-10A provides a compact mixing solution for laboratories, PVC manufacturers and material development departments.

It can be used to prepare PVC powder blends, evaluate additive combinations and conduct preliminary mixing trials before scaling up to larger equipment.

Small batch plastic mixer for laboratory powder preparation
SHR-10A manual discharge gate and cooling chamber assembly on 10L laboratory high-speed mixer



Why Use a Laboratory Mixer for PVC Formulation?

A laboratory mixer allows PVC processors to evaluate formulations without using a full-size industrial mixing unit for every trial.

Typical laboratory tasks include:

  • Preparing small PVC dry-blend batches.

  • Evaluating stabilizer and lubricant combinations.

  • Testing pigment and color formulations.

  • Comparing different filler ratios.

  • Studying mixing temperature and process conditions.

  • Preparing trial material for extrusion evaluation.

Laboratory mixing is especially useful during the development of new PVC pipe, profile, sheet and plate formulations.



Main Features of the SHR-10A PVC Laboratory Mixer

1. 10L Mixing Vessel

The 10L vessel is designed for small-batch laboratory mixing. Its effective working volume is approximately 7L, according to the previously supplied SHR-10A specification.


2. High-Speed Mixing at Laboratory Scale

The SHR-10A uses a high-speed mixing mechanism to generate intensive movement of PVC powder and suitable additives.

The previously published technical information lists a spindle speed of 2000 rpm. Final operating conditions should be confirmed against the machine configuration.


3. Self-Friction Heating

The listed standard heating method is self-friction heating, in which heat is generated through the high-speed mixing process.

Depending on the formulation and target temperature, alternative heating configurations may be discussed with the manufacturer.


4. PLC Automatic Control

The PLC control configuration supports automated operation and process management, helping operators maintain repeatable laboratory mixing procedures.


5. Stainless Steel Mixing Impeller

The machine uses a stainless steel pressure-cast mixing impeller that undergoes dynamic and static balance testing.


6. Cooling Cavity with Spiral Stirring

The cooling arrangement uses spiral stirring to improve material circulation, support temperature reduction and promote complete discharge.

These features are described in the existing SHR-10A technical guide and product information.



Typical PVC Laboratory Mixing Applications

PVC Pipe Formulation

Prepare small batches of PVC powder blends for evaluating formulations intended for pipe extrusion.

PVC Profile Formulation

Support material preparation and additive blending trials for PVC profiles, including window and door profiles.

PVC Sheet and Plate Formulation

Prepare laboratory-scale blends for sheet and plate material development.

PVC Additive Evaluation

Evaluate suitable combinations of stabilizers, lubricants, pigments and fillers before production-scale mixing.



Customization Options

Different PVC formulations may require different mixing and discharge arrangements. The SHR-10A can be discussed with the manufacturer in the following areas:

Heating Configuration

The standard configuration uses self-friction heating. Depending on the process, a version with additional heating or a configuration without additional heating may be evaluated.


Discharge Port Design

The discharge port can be discussed according to the customer's collection method and downstream equipment layout, including side or bottom discharge options.


Vessel and Contact-Part Material

The material of the vessel and product-contact components can be selected according to cleanliness, wear and material compatibility requirements.

The final configuration should be confirmed through technical discussion rather than assuming every option is included as standard.



How to Select a PVC Laboratory Mixer

Before purchasing a PVC laboratory mixer, consider:

  1. PVC formulation: Identify the PVC resin and all additives.

  2. Batch quantity: Confirm the required working volume.

  3. Mixing temperature: Determine the target temperature and heating requirements.

  4. Mixing speed: Confirm the required operating speed and control method.

  5. Discharge design: Consider how the mixed material will be collected.

  6. Vessel material: Confirm material-contact and cleanliness requirements.

  7. Electrical configuration: Provide your local voltage, frequency and phase.



Frequently Asked Questions

Q1: What is a PVC laboratory mixer used for?

It is used to prepare small batches of PVC powder formulations for additive blending, color trials, material development and preliminary extrusion testing.


Q2: Can the SHR-10A mix PVC resin with stabilizers and lubricants?

It is designed for suitable PVC powder mixing applications. PVC resin and compatible stabilizers, lubricants, pigments and fillers can be evaluated according to the required formulation.


Q3: What is the capacity of the SHR-10A?

The SHR-10A has a 10L total vessel capacity and approximately 7L effective working volume, based on the existing product information.


Q4: Does the PVC laboratory mixer have a heating function?

The published SHR-10A specification describes self-friction heating as the standard method. Other heating configurations may be discussed according to process requirements.


Q5: Can this laboratory mixer replace an industrial PVC hot and cold mixing unit?

No. The SHR-10A is intended for laboratory-scale mixing and small-batch trials. Industrial PVC production normally requires larger equipment designed for higher batch volumes.


Q6: Can the discharge port be customized?

The existing technical guide identifies discharge-port customization as an option. The preferred position, size and arrangement should be confirmed when discussing the order.



Request a PVC Laboratory Mixer Quote

Developing a new PVC formulation or testing additives in your laboratory?

Send us your PVC resin type, additive formulation, target mixing temperature and required batch volume. Our engineering team can help evaluate a suitable SHR-10A configuration.

Zhangjiagang-Chenxing-Machinery-Co-Ltd-Zhangjiagang-Chenxing-Machinery-Co-Ltd- (2)Zhangjiagang-Chenxing-Machinery-Co-Ltd- (1)


Previous: 
Next: 

Fill in your material type, product specification and capacity requirement. Our engineer will contact you within 24 hours.

Related Products

Related Articles

      Contacts
Phone:+8615951187228
Email:ceo@cxsljx.com
  Address:No.188,Zhenbei Road, Leyu                             Town, Zhangjiagang City,                               Jiangsu Province
Social Media
© Copyright 2026 Chenxing Machinery All Rights Reserved.
We use cookies to enable all functionalities for best performance during your visit and to improve our services by giving us some insight into how the website is being used. Continued use of our website without having changed your browser settings confirms your acceptance of these cookies. For details please see our privacy policy.
×